14BM2, 14BM2S/G
20BM2, 20BM2S/G
21BM2, 21BM2S/G
????????????
SUB ADJ.ADJ.ADJ.SUB ADJ.
MODEMODEMODEMODE
Y-DELAYOFFSET
SUB TINT (SUB-TINT)
FORWARD : CH DOWN KEY REVERSE : CH UP KEY
MAX VOLUME (SUB-VOL)SUB COLOUR (SUB-COL)
SUB CONTRAST (SUB-CON)SUB BRIGHTNESS (SUB-BRI)SUB SHARPNESS (SUB-SHP)OSD GRB REFERENCE (RGB)CATHODE DRIVE LEVEL (CDL)
MAX HOTEL VOLUME (HTL-VOL)HOTEL PROGRAM NO (HTL-PRG)BLACK LEVEL OFFSET R (CUT-R)BLACK LEVEL OFFSET G (CUT-G)
IC?????????
ADJ.ADJ.3-2
MODEMODEMODE
OPTION
WHITE POINTWHITE POINT
W.P. RED STD. W.T. (DRI-RS)W.P.BLUE STD. W.P. (DRI-BS)W.P. RED COOL W.P. (DRI-RC)
W.P. GREEN STD. W.T. (DRI-GS)W.P. GREEN COOL W.P. (DRI-GC)W.P. BLUE COOL W.P. (DRI-BC)W.P. RED WARM W.P. (DRI-RW)W.P. GREEN WARM W.P. (DRI-GW)W.P. BLUE WARM W.P. (DRI-BW)
??????
AGC &MODEMISC. OPTION MODEAGC &MODE
GEOMETRICGEOMETRIC
VERTICAL SLOPE (V-LIN) VERTICAL AMP (V-AMP) VERTICAL SHIFT (V-CENT) S-CORRECTION (S-COR)
SERVICE MODEAGC TAKE OVER POINT (AGC) HORIZONTAL SHIFT (H-CENT) FORWARD : CH DOWN KEY REVERSE : CH UP KEY * ( ) means OSD display.
e(1)In the Service Mode, Key is used to select the mode in the following order.
2C bus control). (Use
2C bus control and in the
2C bus control include preset-only
3-1
ADJUSTMENT PRECAUTIONS
Short JA122 & JA124 for 1 second and release to switch to the service mode position, and the microprocessor is in input mode. (Adjustment through the IJWS Key to set as well).Press the CH DOWN / UP key on the remote controller to get ready to select the mode one by one.Press the CH DOWN / UP key on the remote controller to select the modes reversibly one by one.Using the VOLUME UP/ DOWN key on the remote controller, the data can be modified.Short JA122 & JA124 for 1 second and release to switch to the normal mode (OFF) position, and the microprocessor is in out of the service mode.Short JA122 & JA124 for 1 second and release to switch to the service mode position and turn on the main power switch. Initial values are automatically preset, only when a new EEPROM is used (Judge with the first 4 bytes).The initial data are preset as listed in pages 4, 5 & 6.Make sure the data need modify or not (Initial data).
FIRST TIME, make sure to short JA122 & JA124 switch to the service mode posi- tion first and then turn on the main power switch. (See 2- 1 above).Precaution: If havenOt done this initiation, it may possibly generate excessive Beam current.
12345123(UA1 Series type RH-IX3368CE Attachment)
This modelOs setting are adjusted in two different ways: though the Iconventional analog manner. The adjustments via the Iitems and variable data.1.Setting the service mode by the microprocessor.2.Factory Presetting.Note:Once the chassis has been assembly together and ready to be POWER ON for the3.For reference please check with memory map
3 |