14AP1
DESCRIPTION OF SCHEMATIC DIAGRAM
SAFETY NOTES:NOTES:
1. DISCONNECT THE AC PLUG FROM THE AC OUTLET BEFORE1. The unit of resistance "ohm" is omitted.
REPLACING PARTS.(K = 1000 ohms, M = Mega ohm).
2. SEMICONDUCTOR HEAT SINKS SHOULD BE REGARDED AS2. All resistors are 1/8 watt, unless otherwise noted.
POTENTIAL SHOCK HAZARDS WHEN THE CHASSIS IS OP-3. All capacitors are ?F, unless otherwise noted. (P = ??F).
ERATING.
IMPORTANT SAFETY NOTICE:VOLTAGE MEASUREMENT CONDITIONS:
PARTS MARKED WITH " a " ( ) ARE IMPOTANT FOR1. Voltages in parenthesis measured with no signal.
MAINTAINING THE SAFETY OF THE SET. BE SURE TO REPLACE2. Voltages without parenthesis measured with 3mV B & W or Col-
THESE PARTS WITH SPECIFIED ONES FOR MAINTAINING THEour signal.
SAFETY AND PERFORMANCE OF THE SET.3. All the voltages in each point are measured with VTVM.
SERVICE PRECAUTION:
THE AREA ENCLOSED BY THIS LINE ( N� - N� ) IS DIRECTLY
CONNECTED WITH AC MAINS VOLTAGE.WAVEFORM MEASUREMENT CONDITIONS:
WHEN SERVICING THE AREA, CONNECT AN ISOLATING TRANS-1. The colour bar generator signal of 1.0V peak applied at pin (24)
FORMER BETWEEN TV RECEIVER AND AC LINE TO ELIMINATEof IC201.
HAZARD OF ELECTRIC SHOCK.2. Approximately 4V AGC bias .